Rockfon MediCare Block
Rockfon MediCare Block
    Rockfon

    Rockfon MediCare Block

    • Specifically designed for use in high-risk, pressurised healthcare environments where high cleanability is required such as emergency rooms, washing facilities and intensive care (compliant with HBN 00-10, TDM 4032:0.6 and HTM 60).
    • For use in operating theatres, seek client approval.
    • Does not contribute to the growth of MRSA, high-rated Bacteriological Class B1 and Clean Room Classification ISO Class 2.
    • Very good cleanability properties, chemical resistance classification ‘Excellent’.
    Specifikim
    • Sound absorption αw: 0.90 (Class A)
      Reaction To Fire B-s1,d0 (EN 13501-1)
      Light Reflection and Light Diffusion 74%
      Humidity and Sag Resistance Up to 100% RH.
      No visible deflection in high humidity
      Surface Durability The high performance inert film of Rockfon MediCare Block provides enhanced durability and water-repellence.
      The film contains DMAc (CAS 127-19-5) in a concentration ≥ 0.1% and < 1% by weight.
      Cleaning Vacuum, Damp cloth, Dry steam cleaning (daily), Resistant to disinfection using Hydrogen Peroxide Vapour, with no impact on aeration time, Chemical resistance: Tested according to ISO 2812-1 (“Determination of resistance to liquids - Part 1: Immersion in liquids other than water”) and classification in accordance with VDI 2083 Part 17. Results are classified as ‘Excellent’ with the following detergents and disinfectants (daily disinfection): – Formalin (37%) – Ammonia (25%) – Hydrogen peroxide (30%) – Sulphuric acid (5%) – Phosphoric acid (30%) – Peracetic acid (15%) – Hydrochloric acid (5%) – Isopropanol (100%) – Sodium hydroxide (5%) – Sodium hypochlorite (15%)
      Clean Room Classification ISO Class 2
      Bacteriological Class M1, NF S 90-351:2013
      Air Pressure Suitable in areas where differential pressure is required.
      When used in combination with:
      -HDC 2 for the 25 mm tile;
      the air leakage rate of less than 0.5m³/h/ m²/Pa under a pressure range of 5 to 40 Pa is achieved.
      The amount of hold down clips (HDC) depends on the tile dimensions and the room size/shape.
      For more information please contact customer service.
    Specifikime teknike
    • Referencë unike22698
    • Familja e produkteveSuspended Ceilings
    • Grupi i produkteveMedicare
    • LlojiObjekt (një objekt të vetëm)
    • Data e botimit2017-12-14
    • Numri i botimit1
    Të ngjashme
    • Materiali kryesorStone Wool
    • Materiali dytësorÇelik
    • Projektuar nëDanimarkë
    Klasifikimi
    • Kategoria BIMobjectNdërtim - Tavanet
    • IFC classificationTavan
    • Kodi ETIMEG000041
    • Emri ETIMConsumer electronics
    • Emrin UNSPSCCeiling panels
    • UNSPSC code30161602
    • Uniclass 2015 CodeSs_30_25_22_90
    • Uniclass 2015 PërshkrimUnit/ modular suspended ceiling systems
    • CSI MasterFormat 2014 Code09 51 00
    • CSI MasterFormat 2014 TitleAcoustical Ceilings
    • OmniClass Number23-15 13 21
    • OmniClass TitleCeiling Panels

    Rajoni i disponueshëm

    Europe
    Åland Islands
    Andorra
    Austri
    Belgjikë
    Bjellorusi
    Bosnjë dhe Hercegovinë
    Bulgari
    Danimarkë
    Estoni
    Finlandë
    Francë
    Gërnzi
    Gjermani
    Gjibraltar
    Greqi
    Holandë
    Hungari
    Irlandë
    Ishujt Faroe
    Ishulli i Njeriut
    Islandë
    Itali
    Jersey
    Kroacia
    Letoni
    Liechtenstein
    Lituani
    Luksemburg
    Mali i Zi
    Maltë
    Maqedonia e Veriut
    Mbretëria e Bashkuar
    Moldovë
    Monaco
    Norvegji
    Poloni
    Portugali
    Qipro
    Qyteti i Vatikanit
    Republika Çeke
    Rumani
    San Marino
    Serbia
    Shqipëri
    Sllovenia
    Slovakia
    Spanjë
    Suedi
    Svalbard dhe Jan Mayen
    Switzerland
    Ukrainë